SURFACE
AERATORS
Features:
The high
speed aerator is simple design mechanical aeration equipment. The
wastewater is pumped through the unit which creates the spray pattern for
introducing oxygen into wastewater. Meanwhile the pumping action creates a
pattern that ensures the maximum kinetic energy is transferred to the
water surface and perform the economical and reliable manner. The
high speed aerators are mostly mounted on floats and used in ponds and
lagoons.
1. Simple
maintenance and installation.
2. Economical
and reliable operation.
3.
High
efficiency of oxygen transfer and mixing.
How
to design the surface aerator for lagoons?
Please click here.
Dimensions:
MODEL |
HP |
A |
B |
C |
D |
E |
F |
H |
W |
SFA-02 |
2 |
1200 |
250 |
200 |
120 |
360 |
100 |
900 |
85 |
SFA-03 |
3 |
1200 |
250 |
200 |
120 |
360 |
100 |
900 |
90 |
SFA-05 |
5 |
1500 |
300 |
320 |
140 |
420 |
100 |
1120 |
130 |
SFA-07 |
7 1/2 |
1500 |
360 |
320 |
280 |
430 |
110 |
1140 |
160 |
SFA-10 |
10 |
1500 |
360 |
320 |
280 |
480 |
110 |
1190 |
180 |
SFA-15 |
15 |
1800 |
500 |
600 |
300 |
580 |
120 |
1600 |
250 |
SFA-20 |
20 |
1800 |
500 |
600 |
300 |
630 |
120 |
1650 |
290 |
SFA-25 |
25 |
1800 |
500 |
600 |
300 |
650 |
120 |
1670 |
350 |
SFA-30 |
30 |
1800 |
500 |
600 |
300 |
700 |
120 |
1720 |
390 |
SFA-40 |
40 |
1800 |
650 |
800 |
340 |
730 |
150 |
2020 |
430 |
SFA-50 |
50 |
1800 |
650 |
800 |
340 |
750 |
150 |
2040 |
430 |
SFA-60 |
60 |
2200 |
800 |
800 |
340 |
820 |
200 |
2160 |
720 |
SFA-75 |
75 |
2200 |
800 |
800 |
370 |
860 |
200 |
2230 |
795 |
SFA-100 |
100 |
2200 |
800 |
800 |
400 |
950 |
200 |
2350 |
1075 |
Constructions:
19.
MOTOR
* Water
Proof, TEFC and Class B insulation or better.
* Housing
drains are provided to drain off internal condensation.
18.
MECHANICAL SEAL
44. WATER GUIDE PANEL ( FRP )
46. SEAL COVER ( FC 25 )
45.FLOAT ( FRP )
*
Float
is completely filled with high density closed cell polyurethane foam
that adds to the structural
stability and prevents sinking.
10.SHAFT ( SUS 410)
* One
piece design eliminates the vibration and constant maintenance
problems.
16.
IMPELLER ( SUS 304)
*
Impeller
is manufactured using the machined pitch process which assures
perfect impeller accuracy performance and without overloading the motor.
47.
WATER INLET PIPE ( FC20 )
Performance:
|
MOTOR
|
AERATOR
|
MODEL
|
HP
|
POLE
|
O2KG/HR
|
DM
|
DZ
|
D
|
Pumping
rate M3/MIN
|
SFA-02
|
2
|
4
|
3
|
6
|
12
|
2-3
|
5
|
SFA-03
|
3
|
4
|
4.2
|
9
|
18
|
3-4
|
7
|
SFA-05
|
5
|
4
|
6.6
|
12
|
24
|
3-4
|
9
|
SFA-07
|
7
1/2
|
4
|
9.6
|
16
|
32
|
3-4
|
11
|
SFA-10
|
10
|
4
|
11.5
|
19
|
38
|
3-4
|
19
|
SFA-15
|
15
|
4
|
16.5
|
27
|
54
|
3-4
|
24
|
SFA-20
|
20
|
4
|
21
|
32
|
64
|
3-4
|
29
|
SFA-25
|
25
|
4
|
27.5
|
36
|
72
|
3-4
|
33
|
SFA-30
|
30
|
4
|
31
|
40
|
80
|
3-4
|
37
|
SFA-40
|
40
|
4
|
38
|
45
|
90
|
5-6
|
46
|
SFA-50
|
50
|
4
|
50
|
50
|
100
|
5-6
|
55
|
SFA-60
|
60
|
4
|
61
|
56
|
112
|
5-6
|
65
|
SFA-75
|
75
|
4
|
73
|
62.5
|
125
|
5-6
|
80
|
SFA-100
|
100
|
4
|
95
|
70
|
140
|
5-6
|
120
|
DZ:
Diameter of mixing zone in meter
DM: Diameter of complete mixing in Meter
— at minimum average velocity of 1.2 meter per second
D: